In chemical procurement, standardizing Ethylene Glycol (MEG) specifications is critical. Misjudging purity, UV transmittance, or moisture content between Industrial Grade and Fiber Grade MEG can cause polymer discoloration, equipment corrosion, or batch failures. This article breaks down key physical-chemical parameters, laboratory testing methods, end-use matching, and a comprehensive procurement checklist for technical buyers.
MEG Name, Formula & Core Physical-Chemical Properties
Ethylene Glycol (commonly abbreviated as EG or MEG for Monoethylene Glycol) is the simplest diol with the chemical formula C2H6O2 and structural formula HOCH2CH2OH.
Note for Procurement: Non-standard abbreviations like “BG” should be avoided in official contracts and Certificates of Analysis (COA). Always specify MEG (CAS 107-21-1).
Key Physical Properties
| Physical Parameter | Standard Value | Procurement Note |
| Molecular Weight | 62.07 g/mol | Theoretical standard |
| Boiling Point | 197.3 °C | At 1 atm atmospheric pressure |
| Melting Point | -12.6 °C | Pure MEG freezing point |
| Flash Point | 111 °C (Closed cup) | Non-flammable but combustible |
| Density (20°C) | 1.112 – 1.115 g/cm³ | Measured with a hydrometer |
| Viscosity (20°C) | ~21 mPa·s | Decreases sharply as temperature rises |
| Water Miscibility | 100% Miscible | Exothermic mixing with slight contraction |
MEG Purity Grades & Key Quality Metrics Comparison
Ethylene Glycol is categorized into Industrial Grade, Fiber Grade (Polyester Grade), and Antifreeze Grade. The core difference lies in impurity control rather than molecular structure
| Specification | Industrial Grade | Fiber Grade (Polyester) | Antifreeze Grade | Impact |
| Purity (wt%) | ≥99.0% | ≥99.8% | ≥99.5% | Higher purity reduces side reactions |
| Moisture (wt%) | ≤0.3% | ≤0.1% | ≤0.2% | Affects freezing point and condensation |
| Acidity (as Acetic Acid) | ≤0.01% | ≤0.005% | ≤0.01% | High acidity causes metallic corrosion |
| Aldehydes (as Formaldehyde) | ≤0.005% | ≤0.001% | — | Causes yellowing in PET products |
| UV Transmittance (220 nm) | Not Required | ≥75% | — | Key criteria for polyester fiber |
| UV Transmittance (275 nm) | Not Required | ≥90% | — | Reflects organic impurity levels |
| Ash Content (wt%) | ≤0.01% | ≤0.005% | ≤0.01% | Prevents pipeline scaling |
| Iron Content | ≤0.0002% | ≤0.0001% | — | Catalytic oxidation risk |
MEG Testing Methods & Standards
For routine incoming cargo inspection, full lab analysis is not always necessary. Moisture, Acidity, and Density are mandatory routine test items, while UV Transmittance depends on the application.
Moisture Content Determination
- Standard Method: Karl Fischer Coulometric Titration (detection limit down to ppm level).
- Field Approximation: Density drops by approximately 0.001 g/cm³ for every 0.1% increase in water content.
Acidity Determination
- Method: Titrate 50 mL MEG sample with 0.01 mol/L NaOH standard solution using phenolphthalein indicator.
- Caution: MEG has relatively high viscosity; shake thoroughly during titration. Off-spec acidity often comes with a sharp odor, signalling acetic or formic acid impurities.
UV Transmittance at 220 nm & 275 nm
- Method: Spectrophotometer using pure water as a blank.
- Analytical Tip: If the sample has a yellowish tint, organic oxidation products are present, indicating failed UV transmittance.
MEG Application Scenarios
Scenario 1: Polyester & PET Resin Production
- Specification: Must use Fiber Grade MEG.
- Risk: Using Industrial Grade MEG will cause aldehyde impurities to participate in side reactions, causing the b-value (yellowness index) of PET chips to rise, resulting in rejection by downstream bottle blowers.
Scenario 2: Automotive Antifreeze & Coolant Formulation

- Specification: Antifreeze Grade or Industrial Grade MEG.
- Freezing Point Curve: Freezing point drops as MEG concentration increases until it reaches a minimum of -48 °C at ~60% v/v concentration. Increasing MEG purity/concentration further will actually raise the freezing point.
Scenario 3: Industrial Secondary Coolants
- Specification: Industrial Grade MEG + Corrosion Inhibitors.
- Risk: At temperatures >60℃, uninhibited MEG degrades into glycolic and oxalic acids, lowering system pH and corroding carbon steel pipes.
Scenario 4: Chemical Synthesis & Solvents
- Specification: Industrial Grade (low moisture variant when needed).
- Risk: Anhydrous chemical reactions require moisture content < 0.05%. Using general industrial grade MEG with 0.2% water will drastically reduce reaction yields.
Storage, Safety & Handling Guidelines
Hygroscopicity Management:MEG is highly hygroscopic. Absorbs 0.1% – 0.2% moisture daily if exposed to ambient air. Storage tanks should be equipped with nitrogen blankets or desiccant air breathers.
Toxicity & Safety: MEG is toxic if ingested (metabolizes into oxalic acid causing renal damage). Due to its sweet taste, clear warning labels must be placed on storage tanks. Never store MEG in food or beverage containers.
Thermal Stability: Avoid prolonged heating above 150℃ to prevent thermal oxidation, acid build-up, and yellowing.